Inverter Battery Calculator: Watts, VA, and backup hours

Share

A summer power cut stops the fan, the Wi-Fi, and work. Too small an inverter makes the fan buzz and wears the battery out early. Too large a set wastes money. Add up the watts you need, then use this calculator for the inverter size in VA and the battery size in Ah.

Inverter and battery size

Add your watts. This gives the inverter size in VA and the battery size in Ah. VA is volt-ampere. Ah is ampere-hour.

A regular fan is about 75 watts. A BLDC fan is about 30 watts.
BLDC uses less power on the same backup
Essential lighting during power cut
43-55 inch TV screen
Work from home essentials
4 Hours
Recommended Configuration
900 VA Pure Sine Wave Inverter
+ 150 Ah Tall Tubular Battery
Total Continuous Load 425 Watts
Minimum Inverter VA Required 638 VA
Calculated Battery Capacity 222 Ah (usable battery is 75% of the charge)
Battery setup 12V Single Battery Setup
Pure sine wave: Use a pure sine wave inverter for a TV, a laptop, or a router. A square wave inverter can make a fan hum and can stress those adapters.

Add the watts you will actually run

Put only the things you need during a cut on the inverter. A geyser, an induction cooktop, or a 1.5 ton AC needs a much larger set, about 5 to 10 kVA, often above ₹1,50,000. A normal home inverter is not for those.

Typical watts for a backup list:

  • Ceiling fans: A regular fan is about 70 to 75 watts at full speed. The calculator default uses 75 watts. A BLDC fan (brushless DC, the low-power fan) is about 28 to 35 watts. The same battery then runs about twice as many fans. Switching the fan choice to BLDC drops a 425 watt list to about 290 watts.
  • LED bulbs: About 9 to 15 watts each. Four bulbs are about 40 to 60 watts.
  • LED TV: A 43 inch to 55 inch set is about 60 to 90 watts while it is on.
  • Wi-Fi and a laptop: The router, the fibre box, and a laptop charger together are about 50 to 70 watts.

A 2BHK or 3BHK with 3 regular fans, 4 LED bulbs, a TV, and Wi-Fi is about 400 to 450 watts while those are on.

Why the inverter is sold in VA, not watts

The inverter box says VA, which is volt-ampere. Your fan label says watts. Watts are VA multiplied by the power factor. For a fan motor, the usual power factor is 0.8. VA is the size the inverter must be rated for. Watts are the work the appliance does.

A 425 watt load at a 0.8 power factor needs 425 / 0.8 = 531 VA. Leave about 20% spare so the inverter is not at full load the whole time. That is about 638 VA. A 900 VA or 1,100 VA inverter covers it. In November 2026 that size is about ₹5,500 to ₹7,500.

Connected Load Recommended Inverter 3 Hours Backup 5 Hours Backup 8 Hours Backup System Voltage
250 Watts (Basic 1BHK) 700 VA to 900 VA 100 Ah Battery 150 Ah Battery 200 Ah Battery 12V Single Battery
425 Watts (Standard 2BHK) 900 VA to 1,100 VA 150 Ah Battery 200 Ah Battery 2x 150 Ah (24V) 12V or 24V Setup
650 Watts (Large 3BHK) 1,100 VA to 1,500 VA 200 Ah Battery 2x 150 Ah (24V) 2x 200 Ah (24V) 24V Double Battery
900 Watts (Heavy / Office) 1,600 VA to 2,200 VA 2x 150 Ah (24V) 2x 200 Ah (24V) 4x 150 Ah (48V) 24V or 48V Setup
Inverter size and tubular battery size for a given load and backup time.

Battery size in Ah, and how much of the charge you can use

Battery size is in ampere-hours (Ah). Two limits sit on top of that number. The inverter wastes some power, about 15%, so efficiency is about 85%. And you should use only about 75% of a lead-acid tubular battery. That usable share is called depth of discharge (DoD). The calculator glosses it as usable battery, 75% of the charge. Draining it further hurts the plates. A battery that could last about 5 years can then fail in under 2 years.

For 425 watts over 4 hours on 12 volts: (425 watts x 4 hours) / (12 volts x 0.85 efficiency x 0.75 usable share) = 222 Ah. A 200 to 220 Ah tall tubular battery gives about 3.8 to 4 hours. A 150 Ah battery gives about 2.7 hours on the same load.

Quick rule before you buy

  1. Buy a pure sine wave inverter: A square-wave model makes the fan buzz, and the noise can disturb a TV or a laptop.
  2. Buy a tall tubular battery: Ask for a C10 or C20 tubular battery. A flat-plate battery, or a car battery, is a poor fit for daily deep backup in an Indian summer.
  3. Change the fans first: A 75 watt fan down to a 28 watt BLDC fan cuts fan power by over 60%. The same battery then lasts much longer.

Related calculators: Solar Rooftop Subsidy Calculator | AC Power Consumption Calculator | Refrigerator Power Calculator | GST & Input Tax Credit Calculator